Company Details

  • Shenzhen Guangyang Zhongkang Technology Co., Ltd

  •  [Guangdong,China]
  • Business Type:Manufacturer
  • Main Mark: Africa , Americas , Asia , East Europe , Europe , Middle East , North Europe , Oceania , West Europe , Worldwide
  • Exporter:81% - 90%
  • Certs:GB, ISO9001, CE, RoHS
  • Description:CE Microcirculation Detector,LED Screen Microcirculation Detector,Blood Capillary Microcirculation Detector
Inquiry Basket ( 0 )

Shenzhen Guangyang Zhongkang Technology Co., Ltd

CE Microcirculation Detector,LED Screen Microcirculation Detector,Blood Capillary Microcirculation Detector

Home > Products > Micirculation Microscope > 8 Inch Micirculation Microscope > LED screen Blood Capillary microcirculation detector CE

LED screen Blood Capillary microcirculation detector CE

Share to:  
    Unit Price: USD 288 - 385 / Set/Sets
    Payment Type: L/C,D/P,Paypal,Money Gram,Western Union
    Incoterm: FOB,CIF,EXW,FCA,CPT,CIP
    Min. Order: 20 Set/Sets
    Delivery Time: 3 Days

Basic Info

Model No.: GY-880

Magnification: 100-500X

Type: Video

Kind of Light Source: Ordinary Light

Packing Dimfnsing: 36*21*33cm

Amplification: 380X

Input: AC Input 100-240V50/60Hz DC

Output: DC12V,2A

Focusing Mechanism: Coaxial Coarse And Fine Adjustment

Built-in Camera: 80 000 Pixels

LCD Monitor: 8inch

Out Package: Corrugated Box

Additional Info

Packaging: Carton Package

Productivity: 1000pcs/Month

Brand: Suyzeko

Transportation: Ocean,Land,Air

Place of Origin: Shenzhen

Supply Ability: 1000pcs/Month

Port: Shenzhen

Product Description

LED screen Blood Capillary Microcirculation detector CE



Microcirculation case analysis:

(1) Hypertension: Enter sticks spasm, slender, showing hook-shaped pipe loop. Reduce the number of blood vessels, blood flow velocity faster.
(2) coronary artery disease: to reduce the number of loop tube, severe deformity, lower output and papillary venous plexus branch expansion, stasis. Erythrocyte aggregation, slow blood flow, blood plasma separation, severe blood was sand-like.
(3) hypotension: pipe loop hidden, more gentle, stiffness, redness of the skin lighter, slow blood flow or stagnation.
(4) chronic bronchitis, asthma, pulmonary heart disease: reducing the number of pipe loops, loop short loop or only see the top or disappear, pipe loop deformity, nipple vein dilation, blood flow is slow. Senile chronic bronchitis, which pipe loop than normal, but between milk under severe venous plexus dilatation.
(5) Diabetes: pipe loop fuzzy, deformity, the wall is not smooth, common flocculent pipe loop, blood viscosity is high, the flow rate is slow, sometimes dotted line shape.
(6) Liver: pipe loop deformity, not smooth, oozing or bleeding, severe red blood cell aggregation, blood flow is slow, severe venous plexus obvious.
(7) peripheral vascular disease (vasculitis): reduce the number of pipe loops, deformity, loop top bleeding, oozing or bleeding, blood flow is slow uneven.
(8) Rheumatology: pipe loop length extension spasms disappeared, pulse movement dilated, blood, red blood cell aggregation, thrombosis obvious, slow flow.
(9) Kidney Disease: pale background, loop week exudation, bleeding, blood stasis classes, reducing the number of pipe loops is not clear, uneven thickness, pipe loop tortuous twisting, spasms end arterioles, venules end opposite the relaxation, flow It slowed down.
(10) atherosclerosis: pipe loop deformation, distortion, wall coarse "twist" and "cross" shape more and bigger blood viscosity, slow blood flow level.



Product introduction:
Microcirculation is the circulation of the blood in the smallest blood vessels,present in the vasculature embedded within organ tissues. This contrasts with macrocirculation, which is the circulation of blood to and from the organs. Microcirculation is composed of terminalarterioles, capillaries capillaries and venules which drain capillary blood. The vessels on the arterial side of the microcirculation are called the arterioles, which are well innervated, are surrounded by smooth musclecells, and are 10-100 µm in diameter.

Microcirculation is usually very smooth, but by high blood lipids, blood viscosity, erythrocyte aggregation, affect cardiovascular disease and other factors, microcirculation appears white tiny blood clots, which with the blood flow in the body.Once the blood vessels become thin, distorted and clog the blood vessels (especially the elderly), there will be a corresponding disease, ranging from dizziness, insomnia, dizziness, numb lips, palpitation, chest tightness. If there is a large area of the brain or heart blockage will cause hemiplegia, language barriers, myocardial infarction. Therefore, early detection of thrombosis should check the microcirculation by actively antithrombotic thrombolysis, and clear the microcirculation, preventive measures.

Currently, the primary means of discovery is microcirculation microcirculation microscopic examination instrument, and general such as CT, MRI, X-ray, B-and so can not be found, so the clinical microcirculation earlier than macroscopic examination has found early diagnosis role.Meanwhile, health groups and immunocompromised people are mainly in the microcirculation, lack of microvascular perfusion, vascular blurred, slow blood flow. By detecting the microcirculation can also quickly find the body in which the current situation in a timely manner as soon as possible be microcirculation, increase resistance and immunity, improve the sub-health conditions.

The Nailfold Capillaroscopy Microcirculation Microscope is an advance medical photoelectric apparatus,equipped with built in special LED light source,used mainly in observation on human nail fold capillary microcirculation or term as video Nailfold capillaroscopy,Such as capillary blood flow, abnormal microcirculation of the vascular structure, cell adhesion, through its powerful 380X(or 240X)optical magnification. Undistorted, real time dynamic video streaming via Sony CCD imaging device onto the LCD monitor screen.

Simply insert the finger to the holder below the optical lens apparatus, fine-tune to fix the focal length and uncover the desired images within seconds.Blood capilliary microcirculation microscope is a non-invasive diagnostic tools, which is gaining large credit among physicians of different specialities in for study of skin blood capilliary network.

Nailfold Micirculation Microscope Detector

Nailfold Micirculation Microscope Detector

Nailfold Micirculation Microscope Detector

Nailfold Micirculation Microscope Detector


Product Features:


It is not a invaded method to inspect the blood micro-circulate situation for the body.
The blood micro-circulate inspect the health situation by view perspective.
It is a contact process. It can search the tip blood capillary position in 5 second. Easy operation (not traditional XY goods).
The micro-image is stable, clear and not move for contact process.
360 times, high definition lens for micro-circulate machine.
Light frame and easy to carry.
Portable light design(250g).
The lens can be exactly adjusted a focal distance to make the image clear.
Lens with LED light, the light can throw straight on a target.
Can be observed in 5 seconds microvascular circulation, simple operation, fast.
Microscopic displays image stability, clear and not shake.
3400 times of microcirculation for high resolution microscopy.
Handheld ultra lightweight design, make observation more action.
With micro focus wheel, can adjust the focal length, more convenience.
Inner objective with LED cold light,can provide accurate projection illumination on the target.
Using non-intrusive way, observing human blood microcirculation status in a timely manner.
Can observation microcirculation For any parts of body.


Application:


A wall of peripheral microcirculation observation.
Skin peripheral microcirculation observation.
Sweat glands observation.
Follicle observation.


Looking for ideal CE Microcirculation Detector Manufacturer & supplier ? We have a wide selection at great prices to help you get creative. All the LED Screen Microcirculation Detector are quality guaranteed. We are China Origin Factory of Blood Capillary Microcirculation Detector. If you have any question, please feel free to contact us.

Product Categories : Micirculation Microscope > 8 Inch Micirculation Microscope

Product Images
  • LED screen Blood Capillary microcirculation detector CE
  • LED screen Blood Capillary microcirculation detector CE
  • LED screen Blood Capillary microcirculation detector CE
  • LED screen Blood Capillary microcirculation detector CE
  • LED screen Blood Capillary microcirculation detector CE
Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Communicate with Supplier?Supplier
Michael Mr. Michael
What can I do for you?
Contact Supplier